Walls on Concrete & Masonry

Walls on concrete and masonry get drywall in one of two ways. Furring channel or Z-bar fastens straight to the wall for a flat face, or a free-standing stud liner wall goes in front where the wall is out of plumb.

Product & Technical Catalogue · PDF

Saturn Metal Cold-Formed Steel Framing Systems Catalogue

Cold-formed 25 gauge steel C-studs for interior walls that carry no axial load. The studs stand in matching floor and ceiling track and are finished with gypsum board on one or both faces. Light and easy to cut and screw.
U-shaped track that holds steel studs at the top and bottom of walls, frames headers and sills at openings, caps joist ends as rim track and nests with a stud to make a box member. Flat web, plain legs, no lips and no knockouts.
A light, hat-shaped galvanized steel channel. Its feet fasten to a masonry or concrete wall, to joists or the structure, or tie under carrying channel; its flat face gives a straight line to screw gypsum board to.
Galvanneal steel corner bead for every 90° outside corner of a drywall wall, column, bulkhead or opening. Its rounded nose gives a straight, hard-wearing corner line, and its 1-1/4″ knurled flanges with key holes hold the joint compound.
Galvanneal steel corner bead for wide-angle outside corners. It is formed at 130° to fit the 135° corners of bay windows, angled walls, chamfered columns and angled bulkheads, with 1-1/4″ knurled flanges that hold the joint compound.
Galvanized steel L trim that gives a clean, finished edge where gypsum board ends: at door and window openings without a wood casing, and where the board meets a suspended ceiling, beam, plaster, masonry or concrete. Fastened after the board is hung and finished with joint compound.
Galvanized steel J trim that caps the end of a gypsum board with a clean, finished line at window and door openings, columns, mullions, concrete, masonry and wall or ceiling intersections. Its 3/8″ leg leaves a straight steel line on the board face, so it needs no joint compound.
Galvanized steel Z-shaped furring with a back flange, a web and a front flange. Fastened to a concrete or masonry wall, it keeps rigid insulation in position and gives a flat line of steel flanges for gypsum board, lath or cladding. The web depth matches the insulation, from 1″ to 6″.
More Products

Direct furring or liner wall

Direct furring Free-standing liner wall
How Furring channel or Z-bar fastened to the wall Studs and track set just off the wall, fixed at floor and ceiling
Space lost About 7/8" plus board, more with insulation Stud depth plus board
Best when The wall is reasonably flat and floor area matters The wall is uneven, or needs deeper insulation, plumbing or electrical runs
Products Furring channel, Z-bar 18 mil studs, standard track

Installing furring channel on masonry

  • Layout. Run the channels at right angles to the board, usually 16" or 24" on centre to suit the board.
  • Fastening. Fasten through both flanges into the concrete or block at every support.
  • Splicing. Nest the ends and tie or screw them together.
  • Levelling. The channel straightens minor wall irregularities and leaves room for wiring behind the board.

Spacing, span and thickness follow the project design and the board manufacturer's limits. Furring channel comes in 18, 33 and 43 mil, 10' and 12'.

Z-bar over rigid insulation

Z-bar is fastened through one flange to the wall with the insulation boards held behind the other. The outer flange gives the board a solid fastening line. Z-bar is formed to suit the insulation thickness, so send the board thickness with the order.

Finishing the edges

Where drywall butts against exposed concrete, masonry or another finish, J-Trim caps the board edge cleanly, with compound optional. L-Trim and corner bead handle openings and outside corners. See drywall beads and trims.

Need a quieter wall against a neighbour? See sound control.

What to send for a quote

Wall area or lineal feet, the method (direct furring or liner wall), insulation thickness if Z-bar is used, and board thickness for the trims.