1
Chat on WhatsApp

Exterior & Curtain Walls

Exterior and curtain walls must resist wind while letting the building move around them. Load-bearing studs cut to full height take the wind load, and slotted track or slide clips at the slab keep floor deflection off the wall.

Product & Technical Catalogue · PDF

Saturn Metal Cold-Formed Steel Framing Systems Catalogue

Cold-formed steel C-studs from 20 to 12 gauge for walls that carry floor and roof loads, wind load, or both. Every stud has stiffening lips on both flanges and oval service knockouts on the web, in the length you order.
Cold-formed steel joists for light steel framed (LSF) floors, mezzanines and roofs. A cold-formed joist floor is light, dry and non-combustible, and it goes up with the same tools and screws as steel stud walls.
U-shaped track that holds steel studs at the top and bottom of walls, frames headers and sills at openings, caps joist ends as rim track and nests with a stud to make a box member. Flat web, plain legs, no lips and no knockouts.
Head-of-wall track fixed to the structure above. Its 2-1/2″ legs have vertical slots and the studs are screwed through the slots, so floors and roofs can move up and down while the studs below stay where they are.
One cold-formed steel U channel with three jobs: the main runner of a suspended ceiling, hung on wire; bridging that runs through the stud knockouts and ties a wall of studs into one line; and bracing that holds every stud against twisting and bowing.
A light, hat-shaped galvanized steel channel. Its feet fasten to a masonry or concrete wall, to joists or the structure, or tie under carrying channel; its flat face gives a straight line to screw gypsum board to.
Galvanized clips that join cold-formed steel framing to itself and to the building: studs to slabs, joists to rims, walls to foundations, brick to backup walls. 23 clips in four families: rigid, deflection and bypass, masonry veneer and specialty.
More Products

Why exterior framing is specified separately

An interior partition is designed to stand up and hold drywall. An exterior wall is designed to resist wind and to accommodate movement in the structure around it. That changes the thickness, the flange, the connection detail and often the length.

Requirement What it changes
Wind load Heavier studs and wider flanges, bridging rows per the engineer
Wall height Studs cut to full height, so no splice
Structural movement Slotted deflection track or a slide clip at the slab
Curtain wall backup Heavy gauge stud with a deflection connection to the slab edge
Brick veneer Brick connectors screwed to the stud web

Infill or bypass

  • Infill walls sit between the slabs. The bottom track is fixed and the top uses deep-leg or slotted deflection track, so the slab above can come down without touching the studs.
  • Bypass walls run past the slab edge. Each stud is tied to the slab with a slotted slide clip that holds it laterally and lets the slab move vertically. Walls set further out use extended slide clips or deflection struts.

Deflection and movement

A building moves. Floors deflect under load, and a wall built tight to the slab above will take that load whether it was designed to or not. A slotted deflection track or a slide clip gives the structure somewhere to go. The gap, clip type and fastening come from the structural drawings. More on the track side in deflection track vs. standard track.

Cladding, insulation and veneer

Furring channel furs out over studs or sheathing to give cladding and siding a straight fastening line. Brick veneer is tied back to the steel stud wall with side-mount, adjustable or surface-mount brick connectors from our clip range. Use G90 coating where the framing sits in high moisture.

Engineering responsibility

Saturn Metal confirms that a profile can be manufactured as specified, in the thickness, width and length required. Structural design, load capacity and code compliance stay with the engineer of record. Dimensional data and standards references for submittal packages are in technical resources.

What to send for a quote

Wall sections or the stud schedule, the slab edge detail, cut lengths per floor and the clip types on the drawings. If a clip is named by another manufacturer's part number, send it and we will confirm the match.