1
Chat on WhatsApp

Interior Partitions

Interior partitions in steel are a stud and track pair finished with gypsum board. Non load-bearing studs stand in standard track, deflection track protects the wall under a moving slab, and corner bead and trims finish the edges.

Product & Technical Catalogue · PDF

Saturn Metal Cold-Formed Steel Framing Systems Catalogue

Cold-formed 25 gauge steel C-studs for interior walls that carry no axial load. The studs stand in matching floor and ceiling track and are finished with gypsum board on one or both faces. Light and easy to cut and screw.
Cold-formed steel C-studs from 20 to 12 gauge for walls that carry floor and roof loads, wind load, or both. Every stud has stiffening lips on both flanges and oval service knockouts on the web, in the length you order.
Cold-formed steel joists for light steel framed (LSF) floors, mezzanines and roofs. A cold-formed joist floor is light, dry and non-combustible, and it goes up with the same tools and screws as steel stud walls.
U-shaped track that holds steel studs at the top and bottom of walls, frames headers and sills at openings, caps joist ends as rim track and nests with a stud to make a box member. Flat web, plain legs, no lips and no knockouts.
Head-of-wall track fixed to the structure above. Its 2-1/2″ legs have vertical slots and the studs are screwed through the slots, so floors and roofs can move up and down while the studs below stay where they are.
Bendable track for curved framing. Short U-shaped segments, linked by folded pleats in the legs and a tab in the web, let a straight length be bent by hand to a smooth curve, then fixed in place and used like standard track to hold the studs.
One cold-formed steel U channel with three jobs: the main runner of a suspended ceiling, hung on wire; bridging that runs through the stud knockouts and ties a wall of studs into one line; and bracing that holds every stud against twisting and bowing.
A plain 90° galvanized steel angle for interior framing. The 1″ × 2″ L-track frames bulkheads, columns and soffits with clean, square edges; the 2″ × 2″ and 1-1/2″ × 1-1/2″ angles connect, stiffen and finish framing wherever a full stud or track is too big.
Single-leg RC1 channel screwed across steel or wood studs and joists, with the gypsum board screwed to the channel instead of the framing. Its slotted web flexes, so less sound passes from the board into the structure.
Galvanneal steel corner bead for every 90° outside corner of a drywall wall, column, bulkhead or opening. Its rounded nose gives a straight, hard-wearing corner line, and its 1-1/4″ knurled flanges with key holes hold the joint compound.
More Products

How the wall goes together

  • Track at floor and ceiling. Standard track anchored to the structure, sized to the stud depth.
  • Studs. 18 mil non load-bearing studs, spaced per the project design. Step up to 33 mil heavier studs for taller walls or heavy finishes.
  • Head of wall. Where the slab above deflects, deep-leg or slotted deflection track, or a deflection side clip, so the wall is not loaded.
  • Bracing. Bridging channel through the stud knockouts, fixed to each stud with a bridging clip. Flat strips give backing for cabinets and fixtures.
  • Finishing. Corner bead on outside corners, L-Trim and J-Trim at openings and where board meets another material.

Matching a stud to a track

Studs and tracks share a width. A 3-5/8" stud sits in a 3-5/8" track, and the thickness of the two is normally the same. What changes between projects is the track, not the stud, and that is usually where a takeoff goes wrong.

Track Use it when
Standard track The partition has no movement requirement at the head
Deep-leg track The head needs room for movement or tolerance
Slotted deflection track The structure above will move, as under a concrete slab or in a tall building
U-Flex track The wall is curved or has a radius feature

More on head-of-wall details in deflection track vs. standard track.

Choosing a thickness

Most interior partitions are 18 mil (25 ga reference). Walls that are unusually tall, carry heavy finishes or support wall-hung loads move up to 33 mil. Check wall height against the stud size in our guide to steel stud limiting heights. Specify by mils, not gauge.

Bulkheads, column wraps and secure rooms

Steel angle gives bulkheads, soffits and column boxes clean, square edges. Where a partition needs to resist forced entry, security mesh goes on the framing behind the board. For a quieter wall, see sound control, and for ceilings, suspended ceilings and bulkheads.

Fire and sound ratings belong to the tested assembly

A rating covers the studs, board, fasteners and details together. Tell us the listed design your project needs and we will quote the framing members it calls for. The listing and the engineer of record govern.

What to send for a quote

Width, thickness, length and quantity for each profile, plus the head condition if you already know it. A takeoff or drawing is faster than a list, because it lets us flag a mismatch before the order is placed.