Interior partitions in steel are a stud and track pair finished with gypsum board. Non load-bearing studs stand in standard track, deflection track protects the wall under a moving slab, and corner bead and trims finish the edges.
Product & Technical Catalogue · PDF
Studs and tracks share a width. A 3-5/8" stud sits in a 3-5/8" track, and the thickness of the two is normally the same. What changes between projects is the track, not the stud, and that is usually where a takeoff goes wrong.
| Track | Use it when |
|---|---|
| Standard track | The partition has no movement requirement at the head |
| Deep-leg track | The head needs room for movement or tolerance |
| Slotted deflection track | The structure above will move, as under a concrete slab or in a tall building |
| U-Flex track | The wall is curved or has a radius feature |
More on head-of-wall details in deflection track vs. standard track.
Most interior partitions are 18 mil (25 ga reference). Walls that are unusually tall, carry heavy finishes or support wall-hung loads move up to 33 mil. Check wall height against the stud size in our guide to steel stud limiting heights. Specify by mils, not gauge.
Steel angle gives bulkheads, soffits and column boxes clean, square edges. Where a partition needs to resist forced entry, security mesh goes on the framing behind the board. For a quieter wall, see sound control, and for ceilings, suspended ceilings and bulkheads.
A rating covers the studs, board, fasteners and details together. Tell us the listed design your project needs and we will quote the framing members it calls for. The listing and the engineer of record govern.
Width, thickness, length and quantity for each profile, plus the head condition if you already know it. A takeoff or drawing is faster than a list, because it lets us flag a mismatch before the order is placed.