1
Chat on WhatsApp

Suspended Ceilings & Bulkheads

Suspended ceilings and bulkheads are built from the structure down. Hanger wire carries the carrying channel, furring channel is tied across it, and perimeter angle finishes the edges, with bulkheads and soffits dropping from the same grid.

Product & Technical Catalogue · PDF

Saturn Metal Cold-Formed Steel Framing Systems Catalogue

Cold-formed 25 gauge steel C-studs for interior walls that carry no axial load. The studs stand in matching floor and ceiling track and are finished with gypsum board on one or both faces. Light and easy to cut and screw.
Bendable track for curved framing. Short U-shaped segments, linked by folded pleats in the legs and a tab in the web, let a straight length be bent by hand to a smooth curve, then fixed in place and used like standard track to hold the studs.
One cold-formed steel U channel with three jobs: the main runner of a suspended ceiling, hung on wire; bridging that runs through the stud knockouts and ties a wall of studs into one line; and bracing that holds every stud against twisting and bowing.
A light, hat-shaped galvanized steel channel. Its feet fasten to a masonry or concrete wall, to joists or the structure, or tie under carrying channel; its flat face gives a straight line to screw gypsum board to.
A plain 90° galvanized steel angle for interior framing. The 1″ × 2″ L-track frames bulkheads, columns and soffits with clean, square edges; the 2″ × 2″ and 1-1/2″ × 1-1/2″ angles connect, stiffen and finish framing wherever a full stud or track is too big.
Straight galvanized steel wire that hangs a suspended ceiling from the building structure. Each wire is tied to the slab, joist or deck above and saddle-tied around the carrying channel below. Offered in 9 ga and 12 ga, cut to 12′ lengths and bundled by gauge.
Thin, soft annealed 18 ga galvanized steel wire, cut to 27″ and 42″ lengths. It ties furring channel to carrying channel at every crossing, ties metal lath to its channels and laps, and holds joints to the lath. It is a tying wire, not a hanger.
Galvanneal steel corner bead for every 90° outside corner of a drywall wall, column, bulkhead or opening. Its rounded nose gives a straight, hard-wearing corner line, and its 1-1/4″ knurled flanges with key holes hold the joint compound.
Galvanneal steel corner bead for wide-angle outside corners. It is formed at 130° to fit the 135° corners of bay windows, angled walls, chamfered columns and angled bulkheads, with 1-1/4″ knurled flanges that hold the joint compound.
More Products

The ceiling system, part by part

Part Job Range
Hanger wire Hangs the ceiling from the structure 9 ga and 12 ga, 12' straight lengths
Carrying channel Main runner, levelled on the wire 3/4" and 1-1/2" U channel, 43 and 54 mil, 10' and 12'
Furring channel Cross members the board screws to 7/8" deep, 1-1/4" face, 18 to 43 mil
Tie wire Ties furring to carrying channel at every crossing 18 ga, 27" and 42"
Perimeter angle Supports and finishes the ceiling edge at the walls 1" x 2" to 2" x 2", 18 and 33 mil, 10'

Typical installation

  • Hang. Hang the wire from the structure and hang the carrying channel on it.
  • Level. Level the carrying channel before anything goes across it.
  • Furring. Run furring channel at right angles below, usually 16" or 24" on centre, and tie or clip it at each crossing.
  • Splice. Lap carrying channel ends and screw them; nest furring channel ends and tie or screw them.

Hanger spacing, channel size and spans follow the project design, the ceiling load and the board manufacturer's limits.

Heavier ceilings and longer spans

1-1/2" x 3/4" carrying channel in 54 mil carries heavier ceilings and longer spans. For lath and plaster ceilings, pencil rod forms the cross-furring and can be bent by hand for domes and vaults.

Bulkheads and soffits

Drops are framed with 18 mil studs and track, and steel angle gives the runners and outside corners a clean, square edge. Curved drops and feature soffits use U-Flex track, which bends by hand to the line marked on site. Finish outside corners with corner bead.

What to send for a quote

The reflected ceiling plan or ceiling area, ceiling height and drop, and any bulkhead elevations. We will check the hanger, channel and angle quantities against the layout.