Suspended ceilings and bulkheads are built from the structure down. Hanger wire carries the carrying channel, furring channel is tied across it, and perimeter angle finishes the edges, with bulkheads and soffits dropping from the same grid.
Product & Technical Catalogue · PDF
| Part | Job | Range |
|---|---|---|
| Hanger wire | Hangs the ceiling from the structure | 9 ga and 12 ga, 12' straight lengths |
| Carrying channel | Main runner, levelled on the wire | 3/4" and 1-1/2" U channel, 43 and 54 mil, 10' and 12' |
| Furring channel | Cross members the board screws to | 7/8" deep, 1-1/4" face, 18 to 43 mil |
| Tie wire | Ties furring to carrying channel at every crossing | 18 ga, 27" and 42" |
| Perimeter angle | Supports and finishes the ceiling edge at the walls | 1" x 2" to 2" x 2", 18 and 33 mil, 10' |
Hanger spacing, channel size and spans follow the project design, the ceiling load and the board manufacturer's limits.
1-1/2" x 3/4" carrying channel in 54 mil carries heavier ceilings and longer spans. For lath and plaster ceilings, pencil rod forms the cross-furring and can be bent by hand for domes and vaults.
Drops are framed with 18 mil studs and track, and steel angle gives the runners and outside corners a clean, square edge. Curved drops and feature soffits use U-Flex track, which bends by hand to the line marked on site. Finish outside corners with corner bead.
The reflected ceiling plan or ceiling area, ceiling height and drop, and any bulkhead elevations. We will check the hanger, channel and angle quantities against the layout.