Hanger Wire

Straight galvanized steel wire that hangs a suspended ceiling from the building structure. Each wire is tied to the slab, joist or deck above and saddle-tied around the carrying channel below. Offered in 9 ga and 12 ga, cut to 12′ lengths and bundled by gauge.
Sizes & gauges
9, 12, 3/16
Lengths
12'
1. Gauge 2 options
2. Standard Length 1 option
Quantity
Minimum 100
Selected configuration
✓

Specifications

Specification
Available options
Status
Gauge
12 • 9
Available
Length
12'
Available
Diameter
9 ga: 0.148" (3.76 mm) • 12 ga: 0.1055" (2.68 mm)
Standard
Bundle
9 ga: 76 pcs • 12 ga: 149 pcs (about 53 lb)
Standard
Tensile Strength
50,000 to 65,000 psi
Standard
Breaking Load (computed)
9 ga: 860–1,118 lb • 12 ga: 437–568 lb
Standard
Material
Galvanized carbon steel wire, ASTM A641
Standard

Product overview

Galvanized Ceiling Suspension Wire, 9 ga and 12 ga, 12' Lengths

Hanger wire hangs suspended drywall and plaster ceilings from the structure above. It comes in 9 ga (0.148″) and 12 ga (0.1055″) galvanized steel wire, in 12′ straight lengths, bundled for site handling. Each wire is fixed to the structure, run down to the carrying channel and wrapped tightly around itself; diagonal wires can be added to resist sideways movement. Wire size, spacing and anchors are set by the ceiling design and the load it carries. Data sheet DS-15 shows suspended ceiling layouts, wire wrapping details, approximate pieces per bundle and reference strength values for orientation.

Product Specifications

Sizes, Gauges & Lengths.

Standard dimensions available for this profile. Need a size, gauge or length that isn’t listed? Our team can confirm custom options for your project.

Specification
Available options
Status
Gauge
12 • 9
Available
Length
12'
Available
Diameter
9 ga: 0.148" (3.76 mm) • 12 ga: 0.1055" (2.68 mm)
Standard
Bundle
9 ga: 76 pcs • 12 ga: 149 pcs (about 53 lb)
Standard
Tensile Strength
50,000 to 65,000 psi
Standard
Breaking Load (computed)
9 ga: 860–1,118 lb • 12 ga: 437–568 lb
Standard
Material
Galvanized carbon steel wire, ASTM A641
Standard

Related Products.

Find related framing components, accessories and complementary products for a more complete project package.

Cold-formed 25 gauge steel C-studs for interior walls that carry no axial load. The studs stand in matching floor and...
Cold-formed steel C-studs from 20 to 12 gauge for walls that carry floor and roof loads, wind load, or both....
Cold-formed steel joists for light steel framed (LSF) floors, mezzanines and roofs. A cold-formed joist floor is light, dry and...
U-shaped track that holds steel studs at the top and bottom of walls, frames headers and sills at openings, caps...

FAQ

Questions Before You Request a Quote.

Find quick answers about product selection, available configurations, installation considerations and ordering details before adding a product to your quote.

9 gauge for heavier ceilings and 12 gauge for lighter ones. The ceiling designer sets the hanger size, spacing and safety factor.

Tie the top end through an anchor, around a joist chord or through an eye lag, run the wire straight and plumb, then saddle-tie it around the carrying channel and twist it tight. Diagonal wires can be added to resist sideways movement.

Computed reference loads at a 4:1 factor are about 215 lb for 9 ga and 109 lb for 12 ga, for the wire alone. The load a hanger may carry also depends on the anchor, the ties and the governing code; the anchor must be rated for the same load.

No. 18 ga tie wire is for tying members together. Hanger wire carries the ceiling load.