1
Chat on WhatsApp
Composite Floor Deck – 1-1/2" profile

Composite Floor Deck

Galvanneal steel deck with embossed webs. During the pour it is the form, carrying the wet concrete and the crew with little or no shoring; once the concrete cures, the embossments lock the slab to the steel and the deck becomes the bottom reinforcement of a composite slab.
Product family
Custom Steel Profiles, Steel Roof Deck & Floor Deck
1. Profile 4 options
2. Cover Width 3 options
3. Gauge 4 options
4. Standard Length Cut to order
5. Coating / Finish 2 options
Quantity
Minimum 100
Selected configuration
✓

Product overview

Embossed Steel Deck for Composite Concrete Slabs

Composite floor deck forms the floor slab and then works with the concrete as its bottom reinforcement. Embossments in the deck webs bond with the concrete, so once it cures the deck and slab act together. Profiles are 1-1/2″ and 3″ deep, standard or inverted, in 22 to 16 ga, with galvanneal finish as standard. The deck carries the wet concrete and construction loads during the pour, often with temporary shoring, and pour stop forms the slab edges. Deck, slab thickness, spans and reinforcement are set by the structural designer. Data sheet DS-28 shows the profiles, slab sections, concrete volumes and accessories.

Product Specifications

Sizes, Gauges & Lengths.

Standard dimensions available for this profile. Need a size, gauge or length that isn’t listed? Our team can confirm custom options for your project.

Specification
Available options
Status
Gauge
22 • 20 • 18 • 16
Available
Profiles
C15 1-1/2" × 6", 36" cover • C3-6 3" × 6", 24" cover • C3-8 3" × 8", 32" cover • C3-12 3" × 12", 36" cover
Available
Laid
Normal or inverted
Available
Slabs
4" to 7" overall
Standard
Webs
Embossed, to bond with the concrete
Standard
Finish
Galvanneal; G90 on request
Available
Accessories
Pour stop • flute closures
Available

Related Products.

Find related framing components, accessories and complementary products for a more complete project package.

Cold-formed 25 gauge steel C-studs for interior walls that carry no axial load. The studs stand in matching floor and...
Cold-formed steel C-studs from 20 to 12 gauge for walls that carry floor and roof loads, wind load, or both....
Cold-formed steel joists for light steel framed (LSF) floors, mezzanines and roofs. A cold-formed joist floor is light, dry and...
U-shaped track that holds steel studs at the top and bottom of walls, frames headers and sills at openings, caps...

FAQ

Questions Before You Request a Quote.

Find quick answers about product selection, available configurations, installation considerations and ordering details before adding a product to your quote.

During the pour it is the form and carries the wet concrete and construction loads. Once the concrete cures, the embossments in the webs lock the slab to the steel, and the deck acts as the bottom reinforcement of the slab.

Little or no shoring, depending on the span. Deck, slab thickness, spans, shoring and reinforcement are set by the structural designer.

The same sheet laid wide flats down, for a heavier, stiffer slab.

Galvanneal is a matte zinc-iron coating that takes paint and spray fireproofing. G90 is available on request.