1
Chat on WhatsApp

Bridging, Bracing & Backing

Bridging, bracing and backing are the three jobs a stud wall needs beyond studs and track. Bridging channel and clips stop studs from twisting, windbrace keeps the frame square during erection, and flat strips or angle give fixtures something solid to hold.

One cold-formed steel U channel with three jobs: the main runner of a suspended ceiling, hung on wire; bridging that runs through the stud knockouts and ties a wall of studs into one line; and bracing that holds every stud against twisting and bowing.
A plain 90° galvanized steel angle for interior framing. The 1″ × 2″ L-track frames bulkheads, columns and soffits with clean, square edges; the 2″ × 2″ and 1-1/2″ × 1-1/2″ angles connect, stiffen and finish framing wherever a full stud or track is too big.
A light galvanized steel brace with a T-shaped section, run diagonally across a framed wall. Its web sits in a single saw kerf and its flat face is nailed to every stud and plate, so it keeps the frame square and resists racking while sheathing, insulation or drywall go straight over it.
Galvanized clips that join cold-formed steel framing to itself and to the building: studs to slabs, joists to rims, walls to foundations, brick to backup walls. 23 clips in four families: rigid, deflection and bypass, masonry veneer and specialty.
Flat galvanized steel in the width and thickness the job needs: horizontal strap bracing on wall studs, strap bridging under floor joists, tension X-bracing of shear walls, and backing, gusset and splice plates and closures. Widths up to 48″, 25 to 12 gauge, in 10′ lengths, up to 12′, or in coil.
More Products

Bridging, bracing and backing at a glance

Job Products What it prevents
Bridging Bridging channel, bridging clip Studs twisting or bowing under wind and axial load
Bracing Windbrace The wall racking out of square during construction
Backing and blocking Flat strips, steel angle Fixtures pulling out of a single stud flange

Bridging rows

  • Channel size. 3/4" x 1/2" channel for 1-5/8" and 2-1/2" studs, 1-1/2" x 1/2" for 3-5/8" and deeper studs, in 43 or 54 mil.
  • Installation. Slide the channel through the knockouts and fix it to every stud with a bridging clip.
  • Splices. Lap the ends and screw them together.

Number of rows and spacing follow the project design. In structural walls they are set by the engineer of record. See load-bearing and mid-rise framing.

Windbrace

A T-shaped galvanized strap, 2" face and 1/2" web in 33 mil, supplied in 11'-3" lengths. Lay it across the wall at about 45°, make one saw cut along its edge, push the web into the cut and nail through the face into every stud and both plates. The flat face sits almost flush, so sheathing, rigid insulation or drywall go straight over it.

Windbrace is a construction bracing aid. It does not replace structural sheathing or an engineered shear wall. Where it is used to meet code bracing rules, the brace type, layout and nailing come from the code and the project designer.

Backing and blocking

Flat strips fixed across the studs, or angle set between them, give a solid line for screws where cabinets, handrails, grab bars, TVs or equipment hang on the wall. Flat strips are cut to length up to 12' in 18 to 97 mil. Plan the backing before the board goes on: it is a few minutes during framing and a repair job after.

What to send for a quote

Stud size and spacing, wall lengths, number of bridging rows, windbrace count, and the backing locations from the interior elevations.